Gas / Fuel / Dual-Fuel Prime Power Solutions

Flexible Fuel Configuration for Reliable Continuous Power Supply

Powermax power generation systems prioritize fuel flexibility and power supply reliability. Based on local fuel availability, energy costs, and project operating requirements, they offer flexible fuel configurations to ensure continuous, stable, and cost-effective power supply for various prime power plants.

✓

Optimized Fuel-Cost Performance
Leverage locally-available low-cost natural gas or associated gas to cut kWh fuel expenditure.

✓

Guaranteed Energy Security
Multi-fuel backup design; seamless auto switch to liquid fuel upon gas supply loss with no load dump, preventing power outages.

✓

Optimized Fuel Operating Costs
Optimize operating strategies based on fuel prices and availability to improve power generation economics.

✓

Improved Environmental Performance
Increasing the natural-gas substitution rate can reduce particulate matter, SOx and carbon intensity compared with 100% HFO operation.

✓

Modular and Flexible Expansion
Support multiple gensets operating in parallel and phased capacity expansion to meet the power requirements of projects of different sizes.

✓

Cogeneration-ready Under Dual-fuel Mode
Waste-heat recovery for CCHP – Combined Cooling, Heat and Power during dual-fuel operation.

Dual-Fuel Operating Modes

Based on local fuel supply, energy prices and project load requirements, select an appropriate operation mode flexibly to balance long-term power supply reliability and operational economy.

100% HFO Mode

100% heavy-fuel-oil operation with natural-gas supply completely disconnected. Optimized for continuous heavy-duty prime-power operation at remote sites lacking gas sources, it retains full performance of the genset under full-load running conditions.

100% Diesel Mode

Pure-diesel independent operation, mainly applied for unit start-up and shut-down procedures, stable low-load running, as well as emergency backup when gas supply system encounters faults. It guarantees reliable power output during mode transition of the whole power station.

NG-Liquid Dual-Fuel Mixed Mode

Mixed combustion of natural gas with diesel or HFO. Maximum gas substitution rate up to 86%, subject to engine load, gas composition, methane number, ambient conditions and liquid-fuel quality.

Flexible Deployment for Reliable On-site Power Stations

Powermax Powermax offers two system solutions: modular containerized power stations and building-housed power stations. Custom configurations are available based on project capacity, operating environment and site conditions.

模块化集装箱电站

Modular Containerized Power System

  • • Flexible capacity expansion from 2 to 50 MW

  • • Modular design for easy transportation and deployment

  • • Supports multi-unit parallel operation and long-term continuous running

  • • Adaptable to complex environments and off-grid project requirements

厂房式电站系统

Building-housed Power Station System

  • • Suitable for medium-to-large long-term power supply projects

  • • Centralized configuration of generator sets and auxiliary systems

  • • Convenient operation management and routine maintenance

  • • Custom system layout tailored to project operating conditions

Modular Containerized Power Plant Functional Area Diagram

厂房式电站系统
厂房式电站系统
  • 1.LNG Fuel Storage & Vaporization Area
    ① LNG Storage Tank (Total Volume: 100 m³); ② Main Air-heated Vaporizer

  • 2.LNG Pressure Regulating Station
    ① Primary Gas Pressure Regulating Station; ② Secondary Gas Pressure Reducing Skid

  • 3.Tank Area
    ① HFO Storage Tank; ② Diesel Storage Tank; ③ HFO Buffer Tank; ④ Residual Oil Tank

  • 4.Auxiliary Equipment Module
    Overall Dimension (L × W × H): 40' GP ISO Container

  • 5.Daily Oil Tank Module
    Overall Dimension (L × W × H): 20' GP ISO Container

  • 6.Power Module
    Overall Dimension (L × W × H): Non-standard Container, 11600 × 3210 × 5044 mm

  • 7.Fuel Handling Module
    Overall Dimension (L × W × H): 20' GP ISO Container

  • 8.Electrical Module
    Overall Dimension (L × W × H): 20' HQ ISO Container

High-Reliability Generator Sets for Long-Term Operation

Powermax supplies diesel, heavy fuel oil and dual-fuel generator sets covering various power requirements. Adopting mature engine technology and flexible fuel configuration schemes, it delivers stable core power equipment for on-site power stations.

G8300/G8320系列
  • G8300 / G8320 Series

  • 1,600–2,500 kW

  • L8 | 50 / 60 Hz

G16V300/G16V320系列
  • G16V300 / G16V320 Series

  • 2,500–5,000 kW

  • V16 | 50 / 60 Hz

Technical Parameters

ITEM8300/8320 TECHNICAL PARAMETER
Genset Type1600 GF2000 GF2500 GF
Rated Engine Power1760 kWm2200 kWm2750 kWm
Rated Genset Power1600 kW2000 kW2500 kW
Engine ModelTNJD G8300TNJD G8320
Cylinder ArrangementL8
Displacement215 L244 L
Bore × Stroke300 × 380 mm320 × 380 mm
Supported Fuel100% HFO / 100% Diesel / NG + HFO / NG + Diesel
Max Gas Substitution RateUp to 86% (depends on load & gas quality)
Gas Supply RequirementCustomized pressure for PNG / LNG‑derived gas
Combustion MethodMixed compression‑ignition
Compression Ratio13:1
Air Intake SystemTurbocharged and intercooled
Cooling SystemRadiator or heat exchanger with cooling tower (Optional)
Governor TypeHydraulic mechanical / electronic (Optional)
HFO Fuel Consumption250 g / kWh ± 3%
Lub Oil Consumption≤ 1.0 g / kWh
Start-up ModeCompressed air
Exhaust Temperature≤ 450 °C
Max Back Pressure≤ 3 kPa
Frequency50 Hz / 60 Hz
Rated Speed500 rpm / 514 rpm600 rpm
Rated Voltage (V)400 / 440 / 6300 / 6600 / 10500 / 13800 V
Phase and Connection3 phase 4 wires / Y type connection
Power Factor0.8 (lagging)
Mode of ExcitationBrushless
AlternatorSiemens / Leroy-Somer (Optional)
Overall Dimension (mm)8904 × 2360 × 32869100 × 2360 × 32869200 × 2360 × 3286
Net Weight (kg)400004500046000
ITEM16V300/16V320 TECHNICAL PARAMETER
Genset Type2500GF3000GF3150 GF3350 GF3600 GF4000 GF5000 GF
Rated Power of Engine2750kWm3300kWm3465 kWm3685 kWm3960 kWm4400 kWm5500 kWm
Rated Power of Genset2500kWe3000kWe3150 kWe3350 kWe3600 kWe4000 kWe5000 kWe
Engine ModelTNJD G16V300TNJD G16V320
Cylinder ArrangementV16
Displacement430 L488 L
Bore × Stroke300 × 380 mm320 × 380 mm
Supported Fuel100% HFO / 100% Diesel / NG + HFO / NG + Diesel
Max Gas Substitution RateUp to 86% (depends on load & gas quality)
Gas Supply RequirementsCustomized pressure for PNG / LNG‑derived gas
Combustion methodMixed compression‑ignition
Compression Ratio13:1
Air Intake SystemTurbocharging + Intercooling
Cooling SystemRadiator or heat exchanger with cooling tower (Optional)
Governor TypeHydraulic mechanical / electronic (Optional)
HFO Fuel Consumption250 g / kWh ± 3%
Lub Oil Consumption≤ 1.0 g / kWh
Start-up ModeCompressed air
Exhaust Temperature≤ 450 ° C
Max Back Pressure≤ 3 kPa
Frequency50 Hz / 60 Hz
Rated Speed500 rpm / 514 rpm600 rpm
Rated Voltage (V)400 / 440 / 6300 / 6600 / 10500 / 13800 V
Phase and Connection3 phase 4 wires / Y type connection
Power Factor0.8 lagging
Excitation MethodBrushless
AlternatorSiemens / Leroy-Somer (Optional)
Overall Dimension (mm)10540 × 2750 × 3100
Net Weight (kg)6000061500635006500067500

Application Scenarios of Diesel / HFO / Dual-Fuel Power Station

Mining & Industrial Sites

Run dual-fuel with site associated gas / PNG to lower HFO use; auto switch to HFO for uninterrupted power if gas fails.

Islands & Offshore Facilities

Supports LNG gasification. Natural gas and HFO act as mutual backups to cut heavy oil logistics cost.

Overseas Projects

Adapt to local fuel diversity. Switch between gas, HFO and diesel to hedge fuel price volatility.

Industrial Parks

Dual-fuel operation via pipeline gas; auto switch to HFO on grid failure to secure plant power.

Primary Power Source for Data Centers

Adopting natural gas + heavy fuel oil dual-fuel configuration, it serves as the primary power source for data centers to ensure continuous and reliable power supply.

Oil & Gas Field

Generate power from wellhead associated gas; reduce routine gas flaring and associated emissions.